Great service after the call back




Review of Five Star Heating & Cooling Group

Just a small issue with the fans not shutting off once the technician left. After he came back, all is good.


Map of Johnstown, OH

Carl was was very fast and knowledgeable.




Review of Five Star Heating & Cooling Group

Great service quick and on time


Map of Johnstown, OH

Great Service




Review of Five Star Heating & Cooling Group


Map of Johnstown, OH

Great Service




Review of Five Star Heating & Cooling Group

Technician was awesome. Knowledgeable, helpful. Did an excellent job.


Fred N.

Fred N.

159526

Near Needles Rd, Johnstown, OH 43031
Michael B.

Michael B.

arrived to Replace WARRANTY OEM Defrost Circuit Board and Replace WARRANTY OEM Defrost Sensor system operating at this time

Near Needles Rd, Johnstown, OH 43031
Johnstown, OH -  arrived to Replace WARRANTY OEM Defrost Circuit Board and Replace WARRANTY OEM Defrost Sensor system operating at this time
Brandon M.

Brandon M.

153809

Near Jug St, Johnstown, OH 43031
Pooya Y.

Pooya Y.

158853

Near Concord Village Cir, Johnstown, OH 43031
Jeffrey P.

Jeffrey P.

150833

Near Beech Rd NW, Johnstown, OH 43031
Michael B.

Michael B.

158890

Near Needles Rd, Johnstown, OH 43031
Pooya Y.

Pooya Y.

158797

Near Concord Village Cir, Johnstown, OH 43031
Josh A.

Josh A.

157349

Near Central Station Pl, Johnstown, OH 43031
Shane C.

Shane C.

157200

Near Central Station Pl, Johnstown, OH 43031
Brandon M.

Brandon M.

Upon arrival customer stated furnace was not heating the home. Upon initial inspection of the gas furnace found that it was out on code 14 ignition proving failure. Referred to code 35 showing flame sensor with corrosion on it and carbon buildup not sensing the flame or not sending the proper amount of millivolts back after checking the flame sensor found it was quite a bit of carbon buildup in deposit on the sensing probe. Cleaned flame sensor off And inserted plane sensor back in the furnace cycled furnace back on let furnace run for 10 minutes and performed combustion test combustion test was 95% efficient 10.1% O2 15 ppm CO. And 96° flu Temp.System running and operating normal upon departure recommend April Aire media filter for better airflow throughout the home. Also recommended Honeywell t10 thermostat with room sensor to help with the temperature difference upstairs

Near Duncan Plains Rd NW, Johnstown, OH 43031
Johnstown, OH - Upon arrival customer stated furnace was not heating the home. Upon initial inspection of the gas furnace found that it was out on code 14 ignition proving failure. Referred to code 35 showing flame sensor with corrosion on it and carbon buildup not sensing the flame or not sending the proper amount of millivolts back after checking the flame sensor found it was quite a bit of carbon buildup in deposit on the sensing probe. Cleaned flame sensor off And inserted plane sensor back in the furnace cycled furnace back on let furnace run for 10 minutes and performed combustion test combustion test was 95% efficient 10.1% O2 15 ppm CO. And 96° flu Temp.System running and operating normal upon departure recommend April Aire media filter for better airflow throughout the home. Also recommended Honeywell t10 thermostat with room sensor to help with the temperature difference upstairs