Hilliard-Dublin Heating & Air Rated 5.0 out of 5 stars based on 1 customer reviews

Map of Delaware, OH

Awesome Price, Great Service!




Review of Hilliard-Dublin Heating & Air


Haidar H.

Haidar H.

Replace circuit board but couldn’t replace the defrost censor. System still frozen on the inside. New defrost sensor is also defective. Ordering new DF sensor and client will call to schedule when the unit has defrosted

Near Rockcreek Dr, Delaware, OH 43015
Delaware, OH - Replace circuit board but couldn’t replace the defrost censor. System still frozen on the inside. New defrost sensor is also defective. Ordering new DF sensor and client will call to schedule when the unit has defrosted
Haidar H.

Haidar H.

Ignitor failing, out of specs and turning a white crust. Collector box has a visible crack, water leaking all over ECM blower motor, which is rusting. Advised client due to water already reaching and rusting the blower motor it’s best to replace the furnace vs parts. Client will wait until major failure to replace

Near Caboose Ln, Delaware, OH 43015
Delaware, OH - Ignitor failing, out of specs and turning a white crust. Collector box has a visible crack, water leaking all over ECM blower motor, which is rusting. Advised client due to water already reaching and rusting the blower motor it’s best to replace the furnace vs parts. Client will wait until major failure to replace
Haidar H.

Haidar H.

I found the pilot assembly needed to be replaced. I informed the customer of the repair and replace options and advised them that the furnace would most likely continue to have issues once the part is fixed. Customer does not want to do anything at this time. System not working at departure due to pilot assembly issues.

Near Joy Ave, Delaware, OH 43015
Delaware, OH - I found the pilot assembly needed to be replaced. I informed the customer of the repair and replace options and advised them that the furnace would most likely continue to have issues once the part is fixed. Customer does not want to do anything at this time. System not working at departure due to pilot assembly issues.
Haidar H.

Haidar H.

Furnace would shut off due to pressure switch opening up. Port on inducer motor for the pressure hose was completely blocked. Cleared blockage, furnace started right away and stayed on. System currently heating at this time.

Near Providence Ln, Delaware, OH 43015
Delaware, OH - Furnace would shut off due to pressure switch opening up. Port on inducer motor for the pressure hose was completely blocked. Cleared blockage, furnace started right away and stayed on. System currently heating at this time.
Haidar H.

Haidar H.

Found issues with the fan limit switch, gas valve, high limit switch, and ignitor. Customer would like to replace system and is working out details with home warranty company.

Near U.S. Hwy 23 N, Delaware, OH 43015
Delaware, OH - Found issues with the fan limit switch, gas valve, high limit switch, and ignitor. Customer would like to replace system and is working out details with home warranty company.
Lucas M.

Lucas M.

I installed a Carrier 96% 80,000 BTU Gas Furnace

Near Marysville Rd, Delaware, OH 43015
Delaware, OH - I installed a Carrier 96% 80,000 BTU Gas Furnace
Haidar H.

Haidar H.

I found that the humidifier is leaking because the filter hasn't been changed. I advised the customer to change the filter yearly.

Near Lackey Old State Rd, Delaware, OH 43015
Adam  S.

Adam S.

I installed Carrier 80% 45,000 BTU Gas Furnace

Near Wabash Ave, Delaware, OH 43015
Delaware, OH - I installed Carrier 80% 45,000 BTU Gas Furnace
Haidar H.

Haidar H.

I replaced OEM Ignitor and adjusted gas pressure down on 2018 Lennox gas furnace. System heating upon departure.

Near Threshing Pl, Delaware, OH 43015
Lucas M.

Lucas M.

I installed a Five Star 96% 40,000 BTU Gas Furnace.

Near Johnson Dr, Delaware, OH 43015
Delaware, OH - I installed a Five Star 96% 40,000 BTU Gas Furnace.